Patrick Schaefer wrote:
> Pin 9 (blue) supplies +5Vstby, pin 14 (green) is PS_on. These two lines
> have to be connected to start the power supply.
Wrong. Pin 14 carries the active-low signal PS_ON# and must be pulled to
ground. See section 3.3.2 of the ATX power supply design guide
(http://www.formfactors.org/developer/specs/ATX_ATX12V_PS_1_1.pdf).
Regards,
Michael