[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Proterm & USR Sportster Question



In article <dwellman.5fwq@bbs.xnet.com>,
Dan Wellman <dwellman@bbs.xnet.com> wrote:
>Hi folks,
>
>I'm using Proterm & a USR Sportster 14.4 modem.  Anyways, when I connect
>to some boards using the Dial menu items, it connects but the countdown
>timer continues to 0.  To get online I have to cancel out of the dial
>dialogue then hit option-t to go to terminal mode.
>
>Anyone have any ideas?  Carrier Detect?  DTR?  Aigh!!

	A friend of mine had this problem with his Intel 14.4 modem.
The problem, I found, was that the modem was set to return extended
result codes. While this is not normally a problem on most modems,
like my Hayes, which report something like this:

CARRIER 9600
PROTOCOL: LAPM
COMPRESSION: V.42bis
CONNECT 19200

	His modem concatenated the whole thing into one line, like

CONNECT 19200/ARQ/LAPM... etc.

	Apparently, proterm can't handle this, and does not detect
the "CONNECT" message. The solution, at least in this case, was
to turn off the extended result codes, so the modem reports only:

CONNECT 19200

	and nothing else... <sigh> I wish manufacturers would agree
upon and adopt one standard instead of many. Of course, this is not
the only example of this problem in industry today... Good luck~

> ___________________________   Dan Wellman    dwellman@bbs.xnet.com


-- 
___________________________________________________________________________
 |___              Chris Deschu                       cdeschu@nyx.cs.du.edu
_|_|con   (610)791-3596   4804 Bowood Street, Center Valley, PA. 18034-9628
:-)|echnologies is IT in the Lehigh Valley for Apple ][ Consulting & Repair