MN wrote:
>Thanks. Re-tested it. Its the monitor! Tried plugging the monitor
>alone, the brick alone, and (brick + CPU) together. The monitor trips
>it 100% of the time.
>
>Guess its time to search for a replacement monitor. The funny thing
>is that the monitor still runs for a good 5-10 mins before tripping
>the breaker... although it is making some hissing sounds.
>
>Not very optimistic about repairing the monitor though...
Interesting. I thought that all monitor power supplies had
fuses that would blow long before any external breaker.
This is a fire prevention requirement.
It's possible that there is a line filter before the fuse, and that
one of the ceramic capacitors in the line filter is shorting and
popping the breaker. But it must be one heck of a short very
near the line cord (or even _in_ the line cord--perhaps near
the strain relief?) to be able to pass enough current to produce
the symptom--repeatedly.
Yes, I'd bet that it is an intermittent short in the line cord.
-michael