"Michael J. Mahon" <mjmahon@aol.com> wrote in message
20040527134105.27551.00000003@mb-m05.aol.com">news:20040527134105.27551.00000003@mb-m05.aol.com...
: Bill Garber wrote:
:
: >"Bill Garber" <willy46pa@comcast DOT net> wrote in message
: >HeCdnWLoL_6F_ijdRVn-hQ@comcast.com">news:HeCdnWLoL_6F_ijdRVn-hQ@comcast.com...
: >:
: >: Hi everyone,
: >:
: >: Ok, I finally got a good cable for my TWGS.
: >: However, I now have an error code coming up,
: >: and it says that if this keeps coming up to
: >: call for service which we all know is impossible.
: >:
: >: Now, the screen says "error code=0202" and to
: >: follow this procedure.
: >
: >Updated error code information.
: >
: >Seems to be revolving around the EEprom.
: >Since the actual X2444P was not available,
: >I purchased 2 different ones that seemed to
: >meet the same requirements.
: >
: >First, the one causing "error code=0202" is
: >an 24C44P, and the other one which causes
: >"error code=0201" is a 93C13N. If anyone knows
: >why this is happening, I would appreciate any
: >input into it. Of course, I would also welcome
: >a location where a X2444P could be acquired.
:
: Before giving it up for dead, try re-writing it by doing
: something that changes the configuration of the
: accelerator--then change it back.

Actually, I can get into the TWGS config menu which
is fine until I open one of the menu items, then the
screen goes wacky. I can still change settings, but
it either crashes on save, or pretends to save and
doesn't. The 0202 message on one chip changes after
I do a save to config, and the one doing a 0201 is
also 0201 with no chip, so I assume that chip is not
being recognized at all.

: Just doing a re-write to an EEPROM will often
: fix a marginal programming job.  (I presume that
: the error message is prompted by getting a bad
: checksum, or other inconsistent reading.)

As stated above, I can work my way into the config
program by doing a reset and quickly pressing Option,
then I leave the control panel and quickly do a OA-
Control-Escape, at which time I can get into the
TWGS menu. I checked the voltages on the EEPROM
socket and I get +5v at Vss, Store, and Recall,
which are normal being Store, and Recall are both
Active Low. I would check their voltage during a write
if I could get the meter on them while pressing all
of the keys necessary while they are connected to the
DVM. I'll see if I can get a reading on that after
the holiday.

Bill @ GarberStreet Enterprizez };-)
Web Site - http://garberstreet.netfirms.com
Email - willy46pa @ comcast DOT net
Change DOT to a dot to contact me



---